Sheet 6841

Page 2

6841-7 – 

Weight 205 lb (93 kg)

Recommended

1813-02-D

Sensitrol

™ 

oil valve

2

(50)

2

5⁄8

  

 (67)

45°

1 (25)

11 (280)

7

¼  

 (185)

13

½  

 sq.

(343)

18

½  

 (470)

6

1⁄16

(154)

35

½  

 

(900)

4 NPT

Main air

connection

6 (152)

10 (254)

12

¾  

 (324)

14 

7⁄16

 (370)

17

 

(430)

2

½  

 

NPT

Gas inlet

¾  

 

NPT

Oil inlet

1

¼  

 

NPT

Atomizing

air inlet

9

5⁄8

 (245)

 

Pipe nipple not furnished by Fives North American Combustion, Inc. Optional (recommended) Sensitrol Oil Valve is not included as part of the burner assembly, and 
must be ordered separately per example below.

 

These dimensions assume the use of a close nipple between burner and Sensitrol Oil Valve.

 

Four hanger rods for suspension in furnace roof.

 

Flame detector must be installed clockwise of pilot as viewed from rear of burner

.

 To 

Order: 

Give complete burner designation.

   

Example:

   6841-8-B25 (6") Burner Complete

  

 

1813-01 

(

½  

") Sensitrol Oil Valve.

6841-8-B25 – 

Weight 560 lb (255 kg)

2

5⁄8

 

(67)

 

¾  

 

NPT

  

– 2 holes for Pilot

and Flame Detector

¾  

 

– NPT Obs. port

2 (50)

4-

5⁄8

 

(16) Slots

on 18

9⁄16

 (470) BC

½  

 

– 13 NC

Thread

42

¼  

 

(1075)

36

¼  

 

(920)

5⁄8

 

(16)

16

½  

 

(420)

24 dia.

(610)

10

¾  

(275)

14

5⁄8

 

(370)

8

3⁄8

(213)

5

½  

 

(140)

3

7⁄8

(99)

4

9⁄16

(115)

2

½  

 

NPT Gas

½  

 

NPT

Compressed air

½  

 

NPT Oil

19

¾  

 

(495)

Recommended

1813-01

Sensitrol

 

oil valve

20°

2

1⁄16

 

(52)

6

 

NPT Main air

11

¼  

(285)

40

3⁄8

 

(1025)

DIMENSIONS

in inches (and mm)

¾  

 NPT – 2 holes for Pilot and Flame Detector

 

or Observation Port. Holes are 15° on either

side of vertical C.

L

Cop

yr

igh

t © 2020 - F

iv

es - All r

igh

ts r

eser

ved | Shee

t 6841 05/13

WARNING: 

Situations dangerous to personnel and property may exist with the operation and maintenance of any combustion equipment. The presence of fuels, oxidants, hot and cold combustion products, hot 

surfaces, electrical power in control and ignition circuits, etc., are inherent with any combustion application. Components in combustion systems may exceed 160°F (71°C) surface temperatures and present hot 
surface contact hazard. Fives North American Combustion, Inc. suggests the use of combustion systems that are in compliance with all Safety Codes, Standards, Regulations and Directives; and care in operation.

DIMENSIONS SHOWN ARE SUBJECT TO CHANGE. PLEASE OBTAIN CERTIFIED PRINTS FROM FIVES NORTH AMERICAN COMBUSTION, INC.

IF SPACE LIMITATIONS OR OTHER CONSIDERATIONS MAKE EXACT DIMENSION(S) CRITICAL

.

Fives North American Combustion, Inc. 

4455 East 71st Street - Cleveland, OH 44105 - USA

www.fi vesgroup.com

CONTACT

fna.sales@fi vesgroup.com
T +1 800 626 3477 - F +1 216 373 4237

Catalog Combustion 2021 - Page 0826

Fives Group
FIVES GROUP
FIVES GROUP-FIVES GROUP-0826-0830

Request Quote

Please provide additional information
Company: *
Name: *
Email: *
Telephone:
Product:
Message:


Privacy Policy and Terms of Service apply.

Fives Group Part Numbers on this Catalog Page
Line Part Number Manufacturer Request Quote
1 6841-8-25 Fives Group Request Quote