OPTIONS
45° or 90° main air connection.
Flanged or slip-on main air connection.
When ordering, specify choice of options as follows:
(P)
for spark ignited pilot
(E)
for direct spark igniton
(Y)
for 45° air connection
(T)
for 90° air connection
(F)
for fl anged air connection
(SW)
slip-on or welding air connection
4570 HiVAM™s for gas only have the same dimensions and practically the same weights as 6570 HiVAMs since the gas burners also have an
"atomizing air" connection for greater fl ame stability
.
Burner
dimensions in inches
Approx.
designation A B D E F G H J K
L
M P Q
lb
4570-9
8 2
½
16
1⁄16
15
13⁄16
3
¾
29
15⁄16
7
7⁄8
8 11
5⁄16
15
13⁄16
23
7⁄8
8
5⁄8
3⁄8
125
4570-12
12 3 19
13⁄16
21
5⁄16
4
¾
42
13⁄32
8 12 14
27⁄32
23
13⁄16
34
5⁄8
11
¾
½
200
Bulletin 4570
Page 3
DIMENSIONS in inches
Example:
4570-9-EYF burner complete with direct spark, 45° air connection and fl anged air connection.
"Y" Connection, SW Style
Main Air SW Style
Slip-Fit or
Welding Conn.
G
A
–pipe size
45°
K
(Same as above)
E
L
1 NPT UV
with 1
¾
hex bushing
R240-2802 Spark Electrode
¾
NPT–Pilot UV
¾
NPT–pilot mixture
1 NPT–Main Flame
Obs. (or UV)
"T" Connection, F Style
2
13⁄16
2
½
NPT
Atomizing Air
3
¼
H
D
M
Main Air Flange
B
-NPT
Gas
E
L
J
A
–pipe size
Q
Flange Thickness
P
F
Cop
yr
igh
t © 2020 - F
iv
es - All r
igh
ts r
eser
ved | Bulle
tin 4570 08/2020
WARNING:
Situations dangerous to personnel and property may exist with the operation and maintenance of any combustion equipment. The presence of fuels, oxidants, hot and cold combustion products, hot
surfaces, electrical power in control and ignition circuits, etc., are inherent with any combustion application. Components in combustion systems may exceed 160°F (71°C) surface temperatures and present hot
surface contact hazard. Fives North American Combustion, Inc. suggests the use of combustion systems that are in compliance with all Safety Codes, Standards, Regulations and Directives; and care in operation.
DIMENSIONS SHOWN ARE SUBJECT TO CHANGE. PLEASE OBTAIN CERTIFIED PRINTS FROM FIVES NORTH AMERICAN COMBUSTION, INC.
IF SPACE LIMITATIONS OR OTHER CONSIDERATIONS MAKE EXACT DIMENSION(S) CRITICAL
.
Dimensions | 4570 HiVAM™
Fives North American Combustion, Inc.
4455 East 71st Street - Cleveland, OH 44105 - USA
www.fi vesgroup.com
CONTACT
fna.sales@fi vesgroup.com
T +1 800 626 3477 - F +1 216 373 4237
Burner
Slip-on Air Connection
Designation
Flange Pattern
OD
B.C.
# Holes
Hole Ø
Actual Pipe OD Size
4570-9
8"
ANSI
13.5
11.75
8
0.88
8
5⁄8
4570-12
12"
RPM
16
14.25
12
0.75
12
¾
Air inlet fl ange dimensions