Air Pressure, osi (UA Pressure Tap)

4442-4-H – 800°F Main Air 

16 

22

Capacity, scfh main air (burning stoichiometric) 

955 

1900 

2850 

3880 

4530  

Max. % XSAir 

1500 

3000 

3000 

3000+  3000+

Max. % XSFuel 

30+ 

30+ 

30+ 

30+ 

30+

Flame Length, in. 

12 

14 

16 

16  

Flame Diameter, in. 

2.5 

2.5 

2.5 

2.5 

2.5  

 

Air Pressure, osi (UA Pressure Tap)

4442-5-H – 800°F Main Air 

16 

22

Capacity, scfh main air (burning stoichiometric) 

1730 

3420 

5050 

6800 

8050  

Max. % XSAir 

2000+  2000+ 

2500+  3000+  3000+

Max. % XSFuel 

30+ 

30+ 

30+ 

30+ 

30+

Flame Length, in. 

20 

22 

22 

24 

25  

Flame Diameter, in. 

2.5 

2.5 

2.5 

2.5

 

Air Pressure, osi (UA Pressure Tap)

4442-6-H – 800°F Main Air 

16 

20

 

Capacity, scfh main air (burning stoichiometric) 

2300 

4800 

7600 

9800 

11000

Max. % XSAir 

2000 

3000+ 

3000+  3000+  3000+ 

Max. % XSFuel 

30+ 

30+ 

30+ 

30+ 

30+ 

Flame Length, in. 

24 

24 

30 

36 

36

Flame Diameter, in. 

6

 

Air Pressure, osi (UA Pressure Tap)

4442-7-H – 800°F Main Air 

16 

20

Capacity, scfh main air (burning stoichiometric) 

3600 

7000 

10800 

13000  15000

Max. % XSAir 

2000+  2000+ 

3000+  3000+  3000+

Max. % XSFuel 

30+ 

30+ 

30+ 

30+ 

30+

Flame Length, in. 

24 

24 

30 

30 

36

Flame Diameter, in. 

  

 

Sheet 4442-1

Page 5

Cop

yr

igh

t © 2020 - F

iv

es - All r

igh

ts r

eser

ved | Shee

t 4442-1 11/12

WARNING: 

Situations dangerous to personnel and property may exist with the operation and maintenance of any combustion equipment. The presence of fuels, oxidants, hot and cold combustion products, hot 

surfaces, electrical power in control and ignition circuits, etc., are inherent with any combustion application. Components in combustion systems may exceed 160°F (71°C) surface temperatures and present hot 
surface contact hazard. Fives North American Combustion, Inc. suggests the use of combustion systems that are in compliance with all Safety Codes, Standards, Regulations and Directives; and care in operation.

Fives North American Combustion, Inc. 

4455 East 71st Street - Cleveland, OH 44105 - USA

www.fi vesgroup.com

CONTACT

fna.sales@fi vesgroup.com
T +1 800 626 3477 - F +1 216 373 4237

Catalog Combustion 2021 - Page 0286

Fives Group
FIVES GROUP
FIVES GROUP-FIVES GROUP-0286-0290

Request Quote

Please provide additional information
Company: *
Name: *
Email: *
Telephone:
Product:
Message:


Privacy Policy and Terms of Service apply.

Fives Group Part Numbers on this Catalog Page
Line Part Number Manufacturer Request Quote
1 4442-6-800 Fives Group Request Quote
2 4442-5-800 Fives Group Request Quote
3 4442-4-800 Fives Group Request Quote
4 4442-7-800 Fives Group Request Quote