SOLENOID VALVES

 

1486A-02, -01, AND 1486A-0

U

L listed and FM approved as main gas safety shutoff  valves (see note) two-way, normally closed, general purpose and watertight 

enclosure for manufactured, natural or propane gas 120/60/110/50 standard (must be installed with solenoid vertical and upright)

NOTE:

 

Valves comply with NFPA standards for systems up to 150,000 Btu/hr. Systems above 150,000 Btu/hr require position indicating valve(s) such as 

the 1486F, 1411, 1412, 1518/19, 1520.]

 

 

 

maximum 

capacity, 

cfh 

    

 

Valve 

pipe 

pressure 

0.6 sp gr gas 

 

 

 

 designation 

size 

psig 

1"wc  

P (2"wc inlet) 

class 

holding 

inrush 

material

 1486A-02 

3⁄8

" 100 

  40 

F 40 70 

brass

 1486A-01 

½  

"   50 

240 

F 25 70 

aluminum

 1486A-0 

¾  

"   50 

250 

F 25 70 

aluminum

coil

VA

Solenoid Gas Valves (Type 2, 3, 3S, 4, and 4X)

 

Valve  

 dimensions in inches

   wt,

 designation 

lb

 1486A-02

 

3⁄8

 

1

7⁄8

 

3

¼  

 

2

11⁄16

 

1

15⁄16

 

1

3⁄8

 

 

 

1486A-01

 

½  

 

2

¾  

  4

1⁄32

 

3

15⁄32

 

2

11⁄32

 

1

¾  

 

1486A-0

 

¾  

   3

5⁄16

    4

15⁄32

 

3

21⁄32

 

2

11⁄32

    1

13⁄16

 

Supplement 4015-1

Page 3

Cop

yr

igh

t © 2-2020 - F

iv

es - All r

igh

ts r

eser

ved. 4015-1_suppl

DIMENSIONS SHOWN ARE SUBJECT TO CHANGE. PLEASE OBTAIN CERTIFIED PRINTS FROM FIVES NORTH AMERICAN COMBUSTION, INC.

IF SPACE LIMITATIONS OR OTHER CONSIDERATIONS MAKE EXACT DIMENSION(S) CRITICAL

.

WARNING: 

Situations dangerous to personnel and property may exist with the operation and maintenance of any combustion equipment. The presence of fuels, oxidants, hot and cold combustion products, hot 

surfaces, electrical power in control and ignition circuits, etc., are inherent with any combustion application. Components in combustion systems may exceed 160°F (71°C) surface temperatures and present hot 
surface contact hazard. Fives North American Combustion, Inc. suggests the use of combustion systems that are in compliance with all Safety Codes, Standards, Regulations and Directives; and care in operation.

Fives North American Combustion, Inc. 

4455 East 71st Street - Cleveland, OH 44105 - USA

www.fi vesgroup.com

CONTACT

fna.sales@fi vesgroup.com
T +1 800 626 3477 - F +1 216 373 4237

Catalog Combustion 2021 - Page 0078

Fives Group
FIVES GROUP
FIVES GROUP-FIVES GROUP-0078-0082

Request Quote

Please provide additional information
Company: *
Name: *
Email: *
Telephone:
Product:
Message:


Privacy Policy and Terms of Service apply.

Fives Group Part Numbers on this Catalog Page
Line Part Number Manufacturer Request Quote
1 120/60/1 Fives Group Request Quote